Commscope ConQuest Conduit Construction Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Comunicação Commscope ConQuest Conduit Construction. CommScope ConQuest Conduit Construction User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 79
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Broadband Applications
and Construction Manual
ConQuest
®
Conduit Products
Vista de página 0
1 2 3 4 5 6 ... 78 79

Resumo do Conteúdo

Página 1 - Broadband Applications

Broadband Applications and Construction ManualConQuest® Conduit Products

Página 2

Handling - Receiving a ShipmentTrouble-free unloading begins with letting your CommScope Customer Service Representative know of any special packaging

Página 3 - Table of Contents

Unloading ConQuest® ProductsUnloading at a DockUse a pallet jack or forklift to remove all products on pallets. Remove any blocking materials for the

Página 4 - 0.1 Table of Contents

Unloading ConQuest® ProductsUnloading With a ForkliftWhen unloading or moving reels with a forklift care must be taken. First check that the forklift

Página 5 - Product Line

Product Identification (Reel Tag)Each reel tag for CIC (as shown below) shall provide the following information and instructions:Shown: typical reel t

Página 6 - ConQuest

3.1 General Conduit Installation Practices Pay-OffPay-OffWhen installing ConQuest, pay-off the reel from underneath and in as direct a line as po

Página 7 - Toneable Conduit

General Conduit Installation Practices 3.2 AttachmentAttaching to ConQuest®Some installation methods require an attachment to the ConQuest conduit

Página 8 - Empty Conduit

3.3 General Conduit Installation Practices Cutting ConQueust®Cutting ConQuest®Several tools have been found useful for the purpose of cutting Co

Página 9 - Rural Utilities Service (RUS)

General Conduit Installation Practices 3.4 Bending ConQuest®Bending ConQuest® (Underground)ConQuest can be easily shaped by rolling a bend into it

Página 10 - Inspection of a Shipment

3.5 General Conduit Installation Practices Mechanical StressMechanical StressRegardless of the installation method, mechanical stress is of grea

Página 11 - Products

Underground Installation Methods 4.1 IntroductionUnderground Installation MethodsConduit was designed for underground installations. Making it poss

Página 13 - Product Identification

Open Trench Installation MethodTrenching is accomplished with specialized trenching tractors which cut the trench and remove the soil in a single acti

Página 14 - INCORRECT CORRECT

Underground Installation Methods 4.3 Open Trench - Moving ReelOpen Trench - Moving Reel Installation Method Moving Reel InstallationPrior to insta

Página 15 - Attaching to ConQuest

4.4 Underground Installation Methods Open Trench - Stationary Reel MethodOpen Trench - Stationary Reel Installation MethodStationary Reel Instal

Página 16 - Cutting ConQuest

Underground Installation Methods 4.5 Open Trench - BackfillingOpen Trench Backfilling MethodIt is best to place the softest soil directly on and a

Página 17 - (Underground)

4.6 Underground Installation Methods Boring (Conventional Bores)Conventional Boring Installation MethodMechanical Boring Machines may be utilize

Página 18 - Mechanical Stress

Underground Installation Methods 4.7 HDD - Horizontal Directional BoringDirectional Bores*Directional boring is accomplished by using a steerable

Página 19 - Introduction

The Drilling Square*The factors that make a successful bore are too interrelated to be able to point a finger at any one of them as being the cause of

Página 20 - Open Trench Methods

FluidThere is no universal soil therefore there is no universal drilling fluid. Drilling fluid provides soil stabilization, lubrication, a means to ca

Página 21 - Open Trench - Moving Reel

4.10 Underground Installation Methods Static PlowingStatic Plowing MethodA tractor moves slowly forward as the blade splits the earth and places

Página 22 - Pull conduit from under

Underground Installation Methods 4.11 Vibratory Static PlowingVibratory Plowing MethodVibratory plowing can offer substantial productivity gains o

Página 23 - Open Trench - Backfilling

Table of ContentsSection 1 ...Introduction 1.1 ConQuest Conduit Product Line 1.2 Cable-In-Conduit 1.3 Toneable Con

Página 24

4.12 Underground Installation Methods Handling Underground ObstructionsHandling ObstructionsIf obstructions (tree roots, large rocks, etc) are en

Página 25 - Directional Bores

Underground Installation Methods 4.13 Pull Plow MethodPull Plow MethodThis method requires the use of a vibrator box attachment. Select a plow bla

Página 26 - Soil Identification

4.14 Underground Installation Methods Rip and Plow MethodPull PlowingUse a plow blade with a circular end approximately 1½ - 2” in diameter. This

Página 27 - The Drilling Square

Underground Installation Methods 4.15 Existing ConduitExisting Conduit InstallationConQuest products are also designed to be placed into existing

Página 28 - Typical static plow setup

4.16 Underground Installation Methods Submarine InstallationSubmarine ConstructionOccasionally there will be a need to install conduit underwater

Página 29 - Vibratory Plowing Method

Underground Installation Methods 4.17 Submarine InstallationSubmarine Plowing MethodThere are two basic methods of submarine construction used, Su

Página 30

4.18 Underground Installation Methods Submarine InstallationFloor Surface PlacementIn this method of construction, the conduit is placed on the f

Página 31 - Start blade in

Underground Installation Methods 4.19 Submarine InstallationSo How Much Weight is Needed?To calculate the weight needed to overcome buoyancy the a

Página 32 - Rip and Plow Method

4.20 Underground Installation Methods Underground Placement EquipmentUnderground Equipment Shoe, CableThis equipment is used to route conduit thr

Página 33 - Existing Conduit

Pulling Cable into Conduit 5.1 OverviewPulling Cable into ConduitThere are many variables to consider when pulling cables, and each pull is conside

Página 34 - Submarine Installation

Section 6 ...Aerial Installation 6.1 Introduction 6.2 Back-Pull/Stationary Reel Method 6.2 Setup Chute Placement

Página 35 - Submarine Plowing Method

5.2 Pulling Cable into Conduit Route GeometryRoute GeometryRoute geometry is an important contributor to pulling tension. The lowest pulling ten

Página 36 - Floor Surface Placement

Pulling Cable into Conduit 5.3 Fill PercentageFill PercentageThe fill percentage, sometimes referred to as fill ratio, is the amount of space that

Página 37 - So How Much Weight is Needed?

5.4 Pulling Cable into Conduit Pulling Multiple CablesPulling Multiple CablesSlings or harnesses are designed to attach multiple cables or inner

Página 38 - Underground Equipment

Pulling Cable into Conduit 5.5 Pulling Multiple CablesBack TensionBack tension is the amount of force needed to pull cable directly from the reel.

Página 39 - Pulling Cable into Conduit

Pull CalculationsMaximum pull lengths, pulling tension at the end of a straight section of conduit, pulling tension at the end of a bend, and sidewall

Página 40 - Route Geometry

Aerial Installation 6.1 OverviewAerial InstallationThere are many applications for aerial conduit, some of which are road crossings, rail crossings

Página 41 - Fill Percentage

6.2 Aerial Installation Back-Pull/Stationary Reel MethodBack-Pull/Stationary Reel MethodThe back-pull / stationary reel method is the usual meth

Página 42 - Pulling Multiple Cables

Aerial Installation 6.3 Back-Pull/Stationary Reel MethodCable Puller Set-UpPlace an appropriate cable grip on each conduit. Secure the grip to the

Página 43 - Back Tension

6.4 Aerial Installation Back-Pull/Stationary Reel MethodPassing the Cable Puller at PolesPull the cable puller to the pole and release the tensi

Página 44 - Pull Calculations

Aerial Installation 6.5 LashingInstallation – Overlashing Existing CableOverlashing conduit onto existing cable plant is similar to installing cond

Página 45 - Overview

Introduction to the ConQuest® Product LineCommScope’s ConQuest product line features select grade high-density polyethylene (HDPE) conduit with value-

Página 46

6.6 Aerial Installation LashingAttach the Lashing Wire ClampPlace the lasher on the strand. Wrap the lashing wire twice around the strand in the

Página 47

Aerial Installation 6.7 LashingAerial EquipmentSet-Up ChuteA set-up chute is used to guide the conduit from the reel trailer to the strand. Single

Página 48

7.1 ConQuest® Toneable Conduit™ Product OverviewCommScope toneable conduit utilizes an embedded 18 AWG tone wire to facilitate conduit location o

Página 49 - Lashing

ConQuest® Toneable Conduit™ 7.2 CouplingTable 1Conduit SizeCU-Clad Wire Size AWGOutside Diameter(inches)Wall Thick-ness(inches)Nominal InnerDiameter

Página 50 - Lashing

7.3 ConQuest® Toneable ConduitTM CouplingTo install ConQuest® toneable conduit, employ standard HDPE conduit installation procedures. When conduit

Página 51 - Aerial Equipment

ConQuest® Toneable ConduitTM 7.4 Coupling Figure 4Join the conduits with an approved coupler according to the manufacturer’s directions.Strip back 5/

Página 52 - Figure 1

7.5 ConQuest® Toneable ConduitTM CouplingInsert the tone wires into the gel-filled connector fully onto both wire ends, and twist (clockwise) unti

Página 53 - Coupling

ConQuest® Toneable ConduitTM 7.6 ToningThe Function of ToningToning is a method of using a generated signal, or ‘tone’, that is transmitted over a co

Página 54 - Figure 2

8.1 Appendix Conduit Cutting Tools and AccessoriesBasket Grip / Pulling GripThis reusable grip, woven from strands of stainless steel, acts like

Página 55 - Figure 7

Underground Equipment Shoe, CableThis equipment is used to route conduit through manholes while the conduit is being pulled into place. Placement of t

Página 56 - Figure: 9

1.2 Introduction ConQuest® Cable-in-Conduit (CIC)ConQuest® Cable-in-Conduit (CIC) Product FamilyConQuest Cable-in-Conduit is factory pre-assembled

Página 57 - The Function of Toning

Aerial EquipmentSet-Up ChuteA set-up chute is used to guide the conduit from the reel trailer to the strand. Single Roller BlockUsed to support condui

Página 58

Pulling SlingUsed to prevent both excessive pulling tension and twisting of conduits in multiple conduit installations. It is designed to break should

Página 59

8.5 Appendix Packaging and ShippingConQuest Reel Dimensions and Weight Chart (Standards in Bold)(Flange x Drum x Traverse) *Longer lengths may b

Página 60

Appendix 8.6 Toneable Conduit SpecificationsConduit SizeCU-Clad Wire Size AWGOutside Diameter(inches)Wall Thickness(inches)Nominal InnerDiameter (

Página 61 - Aerial Placement Equipment

Conduit SpecificationsSDR 11 Nominal Minimum Nominal Outside Diameter Wall Thickness Nominal Inner Min. Bend Radius Max. Pulling Weight* Size

Página 62 - 8.5 Appendix

Conduit SpecificationsSCH 40 Nominal Minimum Nominal Outside Diameter Wall Thickness Nominal Inner Min. Bend Radius Max. Pulling Weight* Size

Página 63

Coaxial Data SheetThis data is provided as a means to determine the number of cables that will fit into a conduit. Product Diameter (DOJ)

Página 64 - Conduit Specifications

Fill Percentage CalculationThe fill percentage can be calculated using this formula: • Single cable Where: ACa = Area of the cable ACo = Area of t

Página 65

Maximum Pulling LengthThe maximum pulling length is the longest distance that a cable can be safely pulled through a straight and level conduit. This

Página 66 - Coaxial Data Sheet

Tb = Ts * efa where: Tb = pulling tension at end of bend in pounds Ts = pulling tension at end of straight section entering

Página 67 - Fill Percentage Calculation

Introduction 1.3 ConQuest® Toneable ConduitTMConQuest® Toneable ConduitTMConQuest Toneable Conduit is a select grade high-density conduit with an in

Página 68 - Ts = L * W * f

Calculated Sidewall PressureThis formula is used to calculate the sidewall pressure in bends. The longer the bend is the lower the sidewall pressure

Página 69 - Tb = Ts * e

Reel Setup At ‘A’, Pulling From ‘H’ Pulling Tension Tension @ A = 0 = 0 Sidewall Pressure Tension @ B (Ts1) =

Página 70 - P = Tb / l

Installation SafetyConstruction of underground facilities require a substantial amount of manpower, tools and equipment. Underground and aerial constr

Página 71 -

Underground SafetyTelecommunication construction is typically done within right-of-way dedicated for the routing of other underground systems – munici

Página 72 - Installation Safety

Occupational Safety And Health Administration (OSHA) StandardsOSHA Standards were established in 1970 to help ensure workplace safety. The Standards a

Página 73 - Underground Safety

National Electric Code (NEC) StandardsThe NEC typically identifies the construction techniques and materials necessary in building wiring requirements

Página 74 - Installation Safety

National Electric Safety Code (NESC) Standards The NESC covers supply and communication cables and equipment in underground buried facilities. The rul

Página 75 - Installation Safety

Conduit and Tracer ColorsCommScope manufactures conduit and trac-ers in a variety of colors to meet your specific requirements. However, please note t

Página 76

Legal DisclaimerTHIS MANUAL IS PROVIDED FOR GUIDANCE PURPOSES ONLY AND SHOULD NOT BE USED OR IN ANY WAY RELIED UPON WITHOUT CONSULTATION WITH AND SUPE

Página 77

www.commscope.comVisit our website or contact your local CommScope representative for more information. © 2014 CommScope, Inc. All rights reserved. Al

Página 78 - Legal Disclaimer

ConQuest® Empty ConduitConQuest Empty Conduit is select grade HDPE conduit with or without factory pre-installed pull lines. Empty conduit is availab

Página 79 - CO-107146.1-EN (03/14)

Introduction 1.5 Quality / CertificationQualityCommScope goes the extra mile to insure you receive quality conduit. Dimensional measurements shall

Comentários a estes Manuais